The Balance Scan System is a highly developed precise measurement technique to assess pressure static and dynamic as well as static and dynamic processes. It is possible to exactly assess upper body posture and body fulcrum during seating.

A multifunctional system, measuring strength abilities in particular isometric maximum strength. It provides exact evaluation and documentation of most important parameters that are relevant for body posture and musculature.

A radiation free statodynamic measurement method, that provides important diagnostic information on the spinal column, hip status, head balance, jaw position, body tone, posture, leg and foot loads.

A highly developed and precise technique to measure foot positioning and resulting pressure from static and dynamic treading. Measurement of foot reaction forces, body fulcrum and gait.

SOMNOscreen Sleep Diagnostics records sleep in the familiar domestic environment. Snoring, apnea, respiratory, and sleep stages and other parameters are measured.

The ISST Myo-Bar-Meter is applied in combination with the FaceFormer for comparative, standard-oriented measurements of lip strength and the air permeability of the nose.


The Balance Scan System is a sophisticated and precise measurement technique for detecting pressure forces both in static and dynamic processes. It enables the accurate diagnostic detection and analysis of upper body posture and body fulcrum while sitting.

Balance Scan Measuring Method

Therapy Supported Measurement with High Quality Equipment

The available sensor technology allows the registration of weak strength measurements (important for children) and has a high sampling frequency. The high measurement frequency and the vector analysis are decisive foundations for a high quality individual therapy plan for the patient.

Individually and Medically Based Training Therapy

Besides assessing the diagnostic data, the system is also prepared for biofeedback therapies. Using the acquired data, our specialists are able to design an individually and medically based training therapy for you.

Static and Dynamic Analysis of Posture and Seating Balance

  • Static pressure tests to obtain the pressure conditions during sitting
  • Static balance and center of gravity determinations during sitting to evaluate deficits in posture and imbalances.
  • Evaluation of dynamic pressure dispersion and balance behavior of the body

Advantages for the Patients

  • Quick evaluations
  • Immediate documentation of test results
  • Objective measurement results
  • Foundation for therapeutic interventions

BackSummary



A multifunctional system, measuring strength abilities in particular isometric maximum strength.
It provides exact evaluation and documentation of most important parameters that are relevant for body posture and musculature.

Myoline Professional

Therapeutical Support Measurement Using High Quality Equipment

Myoline Professional

Quick Assessment of Muscle Status and Muscular Imbalances

The Myoline Professional is a multifunctional system, measuring up to 23 points of strength measurement to assess strength abilities in particular isometric maximum strength. The Myoline Professional makes possible the exact assessment and documentation of the most important position relevant to muscle parameters

Individually and Medically Based Training Therapy

Besides assessing the diagnostic measurements, the system is also prepared for biofeedback therapies. Using the measurement data, our specialists can prepare an individually and medically based training plan for you.

Application

  • Training planning, supervision, control testing for professional and fitness sports
  • Muscle imbalances and asymmetries
  • Bilateral comparison of musculature performance
  • Strength capabilities and deficits
  • After injuries and operations
  • Physical disability
  • Paralysis
  • Other disorders

Myoline Professional

Advantages for the Patient

  • Immediate presentation of the measurement data
  • All measurements possible in one system
  • Observation and monitoring
  • Quick assessment
  • Provides a foundation for therapeutical intervention

BackSummary



A radiation free statodynamic measurement method, that provides important diagnostic information on the spinal column, hip status, head balance, jaw position, body tone, posture, leg and foot loads.

Formetric 4D

Therapy Supporting Measurement

The analysis system DIERS formetric 4D technology allows a quick, static and dynamic (functional) and optical measurement of the above mentioned body segments. The process is free of radiation and does not directly contact the body. Multiple clinical diagnoses regarding objective analyses of body tension and posture, scoliosis and all forms of spinal column deformities can be determined.

Scientifically based 4D Scanning Technology
Fast, Without Physical Contact and Radiation, Scientifically Based

Functional analysis of spine and posture with DIERS Formetric 4D

Functional analysis of spine and posture with DIERS Formetric 4D

The newest development of 4D technology is innovative for the entry in the functional clinical measurement techniques, enhancement of measure accuracy (4D averaging) and avoidance of false measurements attributed to posture variations. It allows static measurements, which can be determined through a series of pictures over time while also allowing measurements during body movement (walking, running).

Einsatzspektrum

  • Spinal column position
  • False positioning due to scoliosis
  • Lordosis and Kyphosis
  • Pelvis position
  • Differences in leg lengths
  • False foot positioning
  • Head and jaw positions – Craniomandibular dysfunction (CMD)
  • Functional analysis
  • Deviations and case tendencies
  • Other

Cervical Spine Measurement

With the “cervical spine measurement” module, the mobility (range of motion) of the cervical spine (neck) can be assessed in 3D. The direction of motion, flexion, extension, left lateral flexion as well as right and left and right rotation is measured. The measurement data and asymmetries are able to be pictured graphically.

Pedography

The analysis of the movement apparatus is completed in connection of a foot pressure measurement system. It provides important additional clinical information.

Advantages for the Patient

  • Radiation-free
  • Immediate data retrieval
  • Objective measurement results
  • Foundation for therapeutic interventions

Measurements

  • Static 3D visualization
    – Single view
  • 4D averaging
    – Visualization sequence reduces position variances
    – Exceptional clinical informational value
  • 4D-Dynamisch
    – Assessment of motion
    – Analysis of whole body motion and of the skeleton (spinal column and pelvis)
  • 4D positioning test
    – Assessment of coordination capabilities and muscular deficits
    – Visualization of volume and form changes through reconstruction of the spinal column
  • Romberg test
    – Balance test
  • Mattihaß-Test
    – Arm-holding test

BackSummary



Pedoscan – Foot Pressure and Walking Analysis

Static and dynamic foot pressure and gait analysis techniques

Pedoscan FußbalanceThe Pedoscan system is a highly developed precise measurement technique to assess foot positioning and the initiation of pressure during static and dynamic processes. An exact assessment of the foot reaction forces and the body fulcrum during standing and walking is possible.

Therapy Supported Measurement with High Quality Equipment

The available sensor technology allows the registration of weak strength measurements (important for children) and has a high sampling frequency. The high measurement frequency and the vector analysis are decisive foundations for a high quality individual therapy plan for the patient.

Individually and Medically Based Training Therapy

Besides assessing the diagnostic data, the system is also prepared for biofeedback therapies. Using the acquired data, our specialists are able to design an individually and medically based training therapy for you.

Measurements

  • Static foot pressure measurement to assess pressure characteristics in the standing position
  • Static balance measurement regarding localization of body fulcrum and for each foot and assessment of posture deficits.
  • Walking/running measurements to assess the dynamic pressure distribution on the feet as well as to assess gait and balance characteristics of the body.
Statische & dynamische Fußdruckmessung mit DIERS Pedoscan

Statische & dynamische Fußdruckmessung mit DIERS Pedoscan

Advantages for the Patient

  • Fast examination time
  • Immediate documentation of results
  • Objective measurement results
  • Foundation for therapeutic interventions

BackSummary



Medical Sleep Diagnostics with SOMNOscreen

Therapy Supported Measurement with High Quality Equipment

Medical Sleep Diagnostics with the Miniature SOMNOscreen

Modern Technique – Mobile Measurement

Sleep is measured in-home in the usual setting. Your remain freely mobile and can move without hinderance with the device in the home.

What is Measured?

  • Snoring
  • Apnea and Hypopnea
  • Breathing flow
  • Thoracic and abdominal breathing
  • Periodic limb movement (PLM)
  • Microarousal
  • ECG (EKG), EEG, EOG
  • Blood oxygen saturation
  • Changes in body position
  • Sleep fragmentation, microarousal (small waking reactions)
  • Sleeping states
  • REM recognition and density analysis
  • Blood pressure
  • Epworth Sleepiness Scale (analog)
  • Comparison of sleep profiles

BackSummary



ISST Myo-Bar-Meter

Measuring Lip Strength and Nose Flow

The ISST Myo-Bar Meter is capable of measuring lip strength and the air permeability of the nose (nose flow). The measurements are made in conjunction with the Face Former.

Lippenkraft

ISST-Myo-Bar-Meter: Using the appliance

ISST-Myo-Bar-Meter: Using the appliance

The tension of the lips is a part of muscle function. Eight muscle pairs are responsible for mouth closure and lip movement. The muscles function synchronistically and actively perform a complex pattern of movement. Therefore, measurement of lip strength provides information about the development of the ability to close one’s mouth and the about the extent of activity and function of the muscle groups.

Nose Flow

Nose flow measurement records the air flow through the nose.

ISST-Myo-Bar-MeterThe technique makes it possible in a simple way to measure the flow of respiration before (initial diagnostic), during (course diagnostic) and after (final diagnostic) therapy. Positive changes observed through the Face Form therapy primarily indicate an optimal tension of the nasal mucosa and an achieved cross-section reduction in the nasal muscles. The patient perceives this effect by experiencing improved breathing through the nose.

Goals of IMB Measurement

  • Comparative and standard measurements
  • Exercise and monitoring controls